Winter at home · Kyivpower, heat, your own bank

Poster · rules with numbers

Five rulesof winter without power

Every rule comes with an engine calculation and a source. Not a single number made up.

01

Rule of power

Size for the longest window

A battery for the longest outage window — and recharge within the shortest window with power. A cold battery is no battery.

Engine examplehomegen.backup_power_plan/1Data under review

Input: Two + a child; Basic set; schedule 4/4

A family of three: 4 h without power needs 0.42 kWh. The engine suggests the Portable power station class — 428 W, 0.70 kWh: it lasts ~4 h and recharges in 0.2 h of the 4 h with power.

Energy for 4 h without power
0.42 kWh
Inverter
428 W
Battery
0.70 kWh
Lasts
4 h
Recharge in 4 h of power
0.2 h
Class price (estimate)
UAH 17,000–35,000
00:0006:0012:0018:0024:00
  • no power
  • power on
  • charging 0.2 h
Devices in the calculation (5)
  • Fridge (class A+…A+++)120 W
  • Wi-Fi router + fibre terminal (ONT)15 W
  • LED lamp × 49 W
  • Phone charging × 310 W
  • Laptop × 260 W
Assumptions, warnings and sources

Warnings

  • NoteStarting power: fridge — up to 700 W. The inverter must handle a 855 W peak.
  • NoteA pure sine wave inverter is needed (not “modified sine”) for the fridge compressor and electronic loads.
  • NoteA concept, not a design: the connection to the panel, cable sizes and protection are set by a licensed electrician from the equipment datasheets.
  • LowPart of the data comes from secondary sources or is an estimate — check before buying (see the sources list).

Assumptions

Engine text in Ukrainian.

  • Ліміт мережі на заряд — 3680 Вт (ввідний автомат 16 А); вкажіть свій номінал або виділену потужність.
  • Графік: 4 год без світла / 4 год зі світлом; найдовше вікно без світла — 4 год, найкоротше зі світлом — 4 год.
  • Постійні й циклічні прилади (холодильник, роутер, котел) можуть працювати одночасно; з приладів «за потребою» — найпотужніший плюс 30% решти.
  • Запас тривалої потужності інвертора ×1.25; одночасно стартує лише один двигун чи компресор.
  • Ємність АКБ = потреба / (DoD 90% × ККД інвертора × температурний коефіцієнт 0.98 при 18 °C); для класів — свій ККД і власне споживання інвертора.
  • Прилади «за потребою» без outage_hours працюють у вікно без світла пропорційно до своїх годин на добу.
  • Поки світло є, дім споживає ~105 Вт — це віднімається від ліміту мережі на заряд.
  • Потужність заряду не задано — для кожного класу взято верхню межу; у дешевих ДБЖ заряд слабший: вкажіть charger_w з паспорта.
  • Ресурс АКБ і старіння не враховано: до кінця строку служби ємність LiFePO4 падає до ~80 % — закладіть запас.

Sources

Engine examplehomegen.backup_power_plan/1Data under review

Input: Two + a child; Basic set; schedule 8/4

A family of three: 8 h without power needs 0.84 kWh. The engine suggests the UPS + LiFePO4 battery class — 570 W, 1.44 kWh: it lasts ~8 h and recharges in 1.4 h of the 4 h with power.

Energy for 8 h without power
0.84 kWh
Inverter
570 W
Battery
1.44 kWh
Lasts
8 h
Recharge in 4 h of power
1.4 h
Class price (estimate)
UAH 21,000–47,000
00:0006:0012:0018:0024:00
  • no power
  • power on
  • charging 1.4 h
Devices in the calculation (5)
  • Fridge (class A+…A+++)120 W
  • Wi-Fi router + fibre terminal (ONT)15 W
  • LED lamp × 49 W
  • Phone charging × 310 W
  • Laptop × 260 W
Assumptions, warnings and sources

Warnings

  • NoteStarting power: fridge — up to 700 W. The inverter must handle a 855 W peak.
  • NoteA pure sine wave inverter is needed (not “modified sine”) for the fridge compressor and electronic loads.
  • NoteA concept, not a design: the connection to the panel, cable sizes and protection are set by a licensed electrician from the equipment datasheets.
  • LowPart of the data comes from secondary sources or is an estimate — check before buying (see the sources list).

Assumptions

Engine text in Ukrainian.

  • Ліміт мережі на заряд — 3680 Вт (ввідний автомат 16 А); вкажіть свій номінал або виділену потужність.
  • Графік: 8 год без світла / 4 год зі світлом (важкий); найдовше вікно без світла — 8 год, найкоротше зі світлом — 4 год.
  • Постійні й циклічні прилади (холодильник, роутер, котел) можуть працювати одночасно; з приладів «за потребою» — найпотужніший плюс 30% решти.
  • Запас тривалої потужності інвертора ×1.25; одночасно стартує лише один двигун чи компресор.
  • Ємність АКБ = потреба / (DoD 90% × ККД інвертора × температурний коефіцієнт 0.98 при 18 °C); для класів — свій ККД і власне споживання інвертора.
  • Прилади «за потребою» без outage_hours працюють у вікно без світла пропорційно до своїх годин на добу.
  • Поки світло є, дім споживає ~105 Вт — це віднімається від ліміту мережі на заряд.
  • Потужність заряду не задано — для кожного класу взято верхню межу; у дешевих ДБЖ заряд слабший: вкажіть charger_w з паспорта.
  • Ресурс АКБ і старіння не враховано: до кінця строку служби ємність LiFePO4 падає до ~80 % — закладіть запас.

Sources

Engine examplehomegen.backup_power_plan/1Data under review

Input: Family of three, basic set, schedule 4/4; battery on the balcony at -5 °C

4 h without power needs 0.42 kWh, but no solution class fits — the engine explains why in the warnings below.

Energy for 4 h without power
0.42 kWh
Recharge in 4 h of power
does not make it
  • ImportantAt this temperature a LiFePO4 battery must not be charged: the BMS will block charging. Keep the battery in a warm room or use a battery with a heater.
  • ImportantEven the best suitable system does not recharge the battery: it needs 0.7 h at 1000 W, and power is on for 4 h. Each cycle leaves less charge, and within a day or two the battery is flat. More charging power, a higher grid limit or a smaller load is needed.
  • ImportantNo solution class covers these devices on this schedule. Take heavy devices off the backup (water heater, electric heating, kettle) or consider a generator or a hybrid with a bigger battery.
Devices in the calculation (5)
  • Fridge (class A+…A+++)120 W
  • Wi-Fi router + fibre terminal (ONT)15 W
  • LED lamp × 49 W
  • Phone charging × 310 W
  • Laptop × 260 W
Assumptions, warnings and sources

Warnings

  • ImportantAt this temperature a LiFePO4 battery must not be charged: the BMS will block charging. Keep the battery in a warm room or use a battery with a heater.
  • ImportantEven the best suitable system does not recharge the battery: it needs 0.7 h at 1000 W, and power is on for 4 h. Each cycle leaves less charge, and within a day or two the battery is flat. More charging power, a higher grid limit or a smaller load is needed.
  • ImportantNo solution class covers these devices on this schedule. Take heavy devices off the backup (water heater, electric heating, kettle) or consider a generator or a hybrid with a bigger battery.
  • NoteStarting power: fridge — up to 700 W. The inverter must handle a 855 W peak.
  • NoteA pure sine wave inverter is needed (not “modified sine”) for the fridge compressor and electronic loads.
  • MediumAt -5 °C the usable LiFePO4 capacity is ~80% of nominal; the calculation accounts for it.
  • NoteA concept, not a design: the connection to the panel, cable sizes and protection are set by a licensed electrician from the equipment datasheets.
  • LowPart of the data comes from secondary sources or is an estimate — check before buying (see the sources list).

Assumptions

Engine text in Ukrainian.

  • Ліміт мережі на заряд — 3680 Вт (ввідний автомат 16 А); вкажіть свій номінал або виділену потужність.
  • Графік: 4 год без світла / 4 год зі світлом; найдовше вікно без світла — 4 год, найкоротше зі світлом — 4 год.
  • Постійні й циклічні прилади (холодильник, роутер, котел) можуть працювати одночасно; з приладів «за потребою» — найпотужніший плюс 30% решти.
  • Запас тривалої потужності інвертора ×1.25; одночасно стартує лише один двигун чи компресор.
  • Ємність АКБ = потреба / (DoD 90% × ККД інвертора × температурний коефіцієнт 0.80 при -5 °C); для класів — свій ККД і власне споживання інвертора.
  • Прилади «за потребою» без outage_hours працюють у вікно без світла пропорційно до своїх годин на добу.
  • Поки світло є, дім споживає ~105 Вт — це віднімається від ліміту мережі на заряд.
  • Потужність заряду не задано — для кожного класу взято верхню межу; у дешевих ДБЖ заряд слабший: вкажіть charger_w з паспорта.
  • Ресурс АКБ і старіння не враховано: до кінця строку служби ємність LiFePO4 падає до ~80 % — закладіть запас.

Sources

02

Rule of heat

Promise no degrees

The engine does not calculate heating — there are no rules. A boiler and a heater count only as backup loads.

Heat

We do not calculate apartment heating

The engines' knowledge base has no heating rules (ДБН В.2.5-67 is not loaded), so the site gives no indoor temperature without central heating and no cooling rate. We only count what the engine can: a gas boiler and a heater as loads on the backup.

On backupEnergy per windowInverterClass from the engineClass price (estimate)
No heat: basic set0.42 kWh428 WPortable power stationUAH 17,000–35,000
+ gas boiler (controls and pump)0.81 kWh644 WUPS + LiFePO4 batteryUAH 19,000–43,000
+ oil-filled heater1.62 kWh2,114 WUPS + LiFePO4 batteryUAH 32,000–65,000
03

Rule of fire

The hob — by its datasheet

Induction is counted; a gas hob and the building's water are not.

Hob

The engine does not count a gas hob

In the engine's catalogue a gas hob is not an electric device. Whether it lights without power (electric ignition, flame control) — see your hob's datasheet. An induction hob is counted: pick “+ induction hob” and watch the inverter grow.

Water

We do not calculate water and building pressure

Building pumps, pressure and hot water depend on the building and the water utility. The engines have no rules or data for this — so no promises. Ask your condominium or building manager.

Engine examplehomegen.backup_power_plan/1Data under review

Input: Two + a child; + induction hob; schedule 4/4

A family of three: 4 h without power needs 0.63 kWh. The engine suggests the UPS + LiFePO4 battery class — 2,489 W, 1.20 kWh: it lasts ~4.8 h and recharges in 1.0 h of the 4 h with power.

Energy for 4 h without power
0.63 kWh
Inverter
2,489 W
Battery
1.20 kWh
Lasts
4.8 h
Recharge in 4 h of power
1.0 h
Class price (estimate)
UAH 18,000–42,000
Devices in the calculation (6)
  • Fridge (class A+…A+++)120 W
  • Wi-Fi router + fibre terminal (ONT)15 W
  • LED lamp × 49 W
  • Phone charging × 310 W
  • Laptop × 260 W
  • Induction hob (one zone)1,800 W
Assumptions, warnings and sources

Warnings

  • NoteStarting power: fridge — up to 700 W. The inverter must handle a 2571 W peak.
  • NoteA pure sine wave inverter is needed (not “modified sine”) for the fridge compressor and electronic loads.
  • NoteA concept, not a design: the connection to the panel, cable sizes and protection are set by a licensed electrician from the equipment datasheets.
  • LowPart of the data comes from secondary sources or is an estimate — check before buying (see the sources list).

Assumptions

Engine text in Ukrainian.

  • Ліміт мережі на заряд — 3680 Вт (ввідний автомат 16 А); вкажіть свій номінал або виділену потужність.
  • Графік: 4 год без світла / 4 год зі світлом; найдовше вікно без світла — 4 год, найкоротше зі світлом — 4 год.
  • Постійні й циклічні прилади (холодильник, роутер, котел) можуть працювати одночасно; з приладів «за потребою» — найпотужніший плюс 30% решти.
  • Запас тривалої потужності інвертора ×1.25; одночасно стартує лише один двигун чи компресор.
  • Ємність АКБ = потреба / (DoD 90% × ККД інвертора × температурний коефіцієнт 0.98 при 18 °C); для класів — свій ККД і власне споживання інвертора.
  • Прилади «за потребою» без outage_hours працюють у вікно без світла пропорційно до своїх годин на добу.
  • Поки світло є, дім споживає ~157 Вт — це віднімається від ліміту мережі на заряд.
  • Потужність заряду не задано — для кожного класу взято верхню межу; у дешевих ДБЖ заряд слабший: вкажіть charger_w з паспорта.
  • Ресурс АКБ і старіння не враховано: до кінця строку служби ємність LiFePO4 падає до ~80 % — закладіть запас.

Sources

04

Rule of reserve

From a station to a hybrid

Every solution class for a family of four with a boiler and a hard schedule. Order: fit first, then price.

One family, one schedule — and class prices differ several times over. The engine puts first not the most expensive, but the one that fits.

Solution classFor this setInverterBatteryClass price (estimate)
UPS + LiFePO4 batteryfits687 W2.74 kWhUAH 37,000–73,000
Portable power stationfits563 W2.65 kWhUAH 66,000–133,000
Hybrid inverter + 48 V batteryfits3,000 W5.00 kWhUAH 110,000–230,000
05

Rule of the bank

Your district first

Providers on your own bank only. Where it is empty, we say so; no routes across the river.

3/63/6RIGHT BANKLEFT BANK×

The provider directory is a fictional citygen sample that shows how search on your own bank works: these providers and addresses do not exist. The real directory is kept by an operator — every fact with a source and date.

Engine examplecitygen.city_resolve/1Data under review

Pozniaky

Input: You: Pozniaky; your own bank only; need — works during outages

Your bank is the left bank. The sample has providers in 3 of 6 categories; where it is empty, we say so.

Bank
left bank
District
Дарницький
Categories on the bank
3 / 6
  • Backup power

    [SAMPLE] Монтаж генераторів «Бровари» (вигаданий)

    same bank

    Works during outagesunknown
  • Electrician

    [SAMPLE] Електрик «Деснянський» (вигаданий зразок)

    same bank

    Works during outagesunknown
  • Plumber

    Nothing on your bank in the directory. On the other bank: 1; the service does not route you across the river.

  • Windows & doors

    [SAMPLE] Вікна «Лівий берег» (вигаданий зразок)

    same district

    Works during outagesunknown
  • Renovation

    Nothing on your bank in the directory. On the other bank: 1; the service does not route you across the river.

  • Furniture

    Nothing on your bank in the directory. On the other bank: 1; the service does not route you across the river.

Assumptions, warnings and sources

Warnings

  • NoteCheck air-raid alerts and the state of the bridges in official sources (the «Kyiv Digital» app, «Air Alert»). The service does not know the current state of bridges, roads or air-raid alerts and does not promise a safe trip; power facts come from the directory operator with a date.
  • LowSome reference sources (geography, registers) are flagged for verification.

Assumptions

Engine text in Ukrainian.

  • Берег визначено за місцем «Позняки»: лівий берег.
  • locality = {city, bank, district}; для передмістя district — назва передмістя.

Sources

Engine examplecitygen.city_resolve/1Data under review

Sviatoshyn

Input: You: Sviatoshyn; your own bank only; need — works during outages

Your bank is the right bank. The sample has providers in 3 of 6 categories; where it is empty, we say so.

Bank
right bank
District
Святошинський
Categories on the bank
3 / 6
  • Backup power

    Nothing on your bank in the directory. On the other bank: 1; the service does not route you across the river.

  • Electrician

    Nothing on your bank in the directory. On the other bank: 1; the service does not route you across the river.

  • Plumber

    [SAMPLE] Сантехнік «Голосіїв» (вигаданий зразок)

    same bank

    Works during outagesunknown
  • Windows & doors

    Nothing on your bank in the directory. On the other bank: 1; the service does not route you across the river.

  • Renovation

    [SAMPLE] Ремонт «Солом'янка» (вигаданий зразок)

    neighbouring district

    Works during outagesunknown
  • Furniture

    [SAMPLE] Меблі «Вишневе» (вигаданий зразок)

    nearby suburb

    Works during outagesunknown
Assumptions, warnings and sources

Warnings

  • NoteCheck air-raid alerts and the state of the bridges in official sources (the «Kyiv Digital» app, «Air Alert»). The service does not know the current state of bridges, roads or air-raid alerts and does not promise a safe trip; power facts come from the directory operator with a date.
  • LowSome reference sources (geography, registers) are flagged for verification.

Assumptions

Engine text in Ukrainian.

  • Берег визначено за місцем «Святошин»: правий берег.
  • locality = {city, bank, district}; для передмістя district — назва передмістя.

Sources

Sources with dates

Every source in the engines' envelopes. “Data under review” — secondary sources or estimates.

SourceAs ofStatus
220volt.com.ua — гібридна СЕС 10 кВт Deye + АКБ 10,24 кВт·годOct 3, 2026Data under review
dealgen: дослідження ринку «Сонце, резервне живлення» (03.10.2026)Oct 3, 2026Data under review
Deye SUN-(5–12)K-SG04LP3 / SG03LP1 — даташит гібридного інвертора низьковольтної АКБ 48 ВOct 3, 2026Data under review
EcoFlow DELTA 3 Plus — специфікація виробникаOct 3, 2026Data under review
ek.ua — ціни EcoFlow DELTA 3 Plus в УкраїніOct 3, 2026Data under review
EPREL — європейська база енергетичних етикеток (типові річні споживання холодильників, телевізорів)Oct 3, 2026Data under review
LiFePO4: робоча температура розряду −20…+60 °C, заряд лише вище 0 °C; ємність на холоді нижча (даташити виробників LFP-елементів)Oct 3, 2026Data under review
svitakb.ua — комплект Deye 10 кВт / 10 кВт·годOct 3, 2026Data under review
Victron Energy, «Wiring Unlimited»: спад напруги в колах АКБ, вибір напруги системи 12/24/48 ВOct 3, 2026Data under review
«Київ Цифровий» — офіційний застосунок міста (тривоги, укриття, транспорт)Oct 4, 2026Data under review
«Повітряна тривога» — офіційний застосунок сповіщеньOct 4, 2026checked
Вікіпедія — Список станцій Київського метрополітену (колишні назви)Oct 4, 2026Data under review
Вікіпедія — статті про станції Київського метрополітену (рядок «Район міста»)Oct 4, 2026Data under review
Графіки відключень ОСР (Yasno/ДТЕК): черги та підчерги, погодинні вікнаOct 3, 2026Data under review
ДБЖ (лінійно-інтерактивні та online) із зовнішньою АКБ для котла: типові характеристики українського ринкуOct 3, 2026Data under review
Київська міська рада — адміністративно-територіальний устрій Києва (10 районів)Oct 4, 2026Data under review
КП «Київський метрополітен» — схема ліній і станційOct 4, 2026Data under review
Оцінка проектувальника: деградація модулів, ресурс АКБ, ККД зарядуOct 3, 2026Data under review
Пускові струми двигунів і компресорів: кратність 3–6 до номінального (Victron Energy, Wiring Unlimited; паспорти насосів)Oct 3, 2026Data under review
Типові паспортні потужності побутових приладів (оцінка за паспортами поширених моделей)Oct 3, 2026Data under review
Українська правда — Київрада перейменувала станції метро (18.05.2023)May 18, 2023Data under review

A concept, not a design: how backup is wired to the panel, boiler or hob is decided by a licensed electrician from the equipment datasheets. Class prices are indicative ranges, not a price list.

Neutral — and how we make money

  • Backup classes — no brands, no partners, in the engine's order: fit first, then price.
  • Providers: your bank and your needs first, then proximity, then name. Listing fees do not affect the order — the directory does not even store them.
  • No ratings, reviews or “guarantees”.
  • No partners are connected yet: the “Get offers” button is inactive.

Full disclosure on tools.furnigen.app

Partners are not connected yet. When they are: neutral order, your contacts go only to the partner you name and only with your consent. How we make money

Use it inside Claude or ChatGPT

coming soon

The same calculator runs as an MCP server: your assistant calls it and answers with these numbers, assumptions and sources.

Server address (not live yet)https://mcp.furnigen.app/homegen/mcp
  1. Claude: Settings → Connectors → Add custom connector → paste the address.
  2. ChatGPT: Settings → Apps & Connectors → create a connector (developer mode) → paste the address.

The public server opens after the gateway launch. Until then this address does not answer.

To the rules